CVCS for short, this system in a PWR plant is important for maintaining reactor water chemistry. It includes an ion exchange deep bed system to control pH, remove contaminating ions and radionuclides, and reduce boron concentration when needed. Mixed beds are normally used; some plants also employ a cation or anion exchange resin bed. High quality Nuclear Grade Gravex® resins have been used for more than 25 years in each bed location. Gravex resins are well recognized to be of the highest quality, exceeding nuclear grade specifications. Our commitment to product development has led to innovative products beneficial to plant operations.
Product | Application Area |
---|---|
Gravex GR 1-9 NG (OH) | Nuclear Grade low chloride anion |
Gravex GR 1-9 US Ultra (OH) | Nuclear Grade Ultra low chloride anion |
Gravex GR 2-0 NG (H) | Nuclear Grade cation |
Gravex GR 2-16 NG (H) | Nuclear Grade high capacity cation |
Gravex GR 3-9 NG (H/OH) | Nuclear Grade mixed bed |
Gravex GR 3-16 NG (H/OH) | Nuclear Grade mixed bed with high capacity cation |
Gravex GR 4-9 NG (Li7/OH) | Nuclear Grade mixed bed with lithium-7 form cation |
Gravex GR 7-16 NG (Li7) | Nuclear Grade high capacity lithium-7 form cation |
Gravex GR 4-7 NG (Li7/OH) | Nuclear Grade mixed bed with high capacity lithium-7 form cation |